DETECTOR: Electrochemical fuel cell.
SPECIFICITY: Fuel cell sensor is unaffected by acetone, paint and glue fumes, foods, confections, methane, and practically any other substance found in the human breath.
SAMPLING: Automatic after the subject provides 1.5 liters of breath. A manual sampling feature is also provided.
MEMORY: The result of the last test is stored and can be recalled until the next test is started.
ACCURACY: Meets DOT specifications of ±.005 BrAC up to 0.100 BrAC and ±5% above 0.100 BrAC.
RESPONSE TIME: Within five seconds of sampling, depending on alcohol concentration.
DISPLAY: Large, three-digit LED (9/16” x 5/16”).
AUDIBLE INDICATOR: Beeper signals changes in instrument status.
VISUAL INDICATOR: LEDs are used for alpha prompting of the operator.
INSTRUMENT CONTROL: By microcontroller.
RECOMMENDED OPERATING TEMPERATURE: 23° to 104°F (-5° to 40°C).
CALIBRATION: Automated procedure by either dry gas or wet bath simulator.
DIMENSIONS: 2½” w x 4¾” h x 1¼” d (actual size above).
POWER SUPPLY: Two “AAA” batteries.
WARRANTY: One year, parts and labor.